Products

IECEx Approved Thermocouples

with Termination Entry Gland

Our IECEx approved mineral insulated thermocouple assemblies are manufactured from cable that conforms to IEC 61515 and their semi rigid construction allows them to be bent and formed to suit particular applications without impairing performance.
  • Available in a wide range of protection concepts for Zones 0, 1 & 2 use. See table below for details
  • Temperature classification T6-T1, see here for stand-off requirements
  • Available in thermocouple types K, T, J, N, E, R, S and B
  • Sheath diameters from 1.0mm to 8.0mm in a wide choice of materials
  • Insulated measuring junction gives a floating output with high insulation resistance
  • Terminated in a compression gland pot seal with 50mm PTFE sleeved tails
  • UKAS calibration available.
Available with the following approvals:

Protection Type Description Zone
Ex nA IIC Gc Non-Sparking (Gas) 2
Ex d IIC Gb Flameproof (Gas) 1
Ex ia IIC Ga / IIIC Da Intrinsically Safe (Gas/Dust) 0/20
Ex tb IIIC Db Enclosure (Dust) 21
Ex tc IIIC Dc Enclosure (Dust) 22



Enquiry Form

1. Thermocouple Type


2. Protection Concept


Concept Type Select
Ex d Flameproof/Explosion Proof
Ex ia Intrinsically Safe
Ex nA Non-Sparking
Ex tb Enclosure
Ex tc Enclosure

Your chosen concept is:


Ex d Flameproof/Explosion Proof – Category 2, Zones 1,2 (Gas)
• Ex d IIC T6...T1 Gb Ta = –40°C to 60°C
• Standard EN IEC 60079-1 refers
• Designed to contain an explosion and quench the flame
• Sensors incorporate a suitable heavy duty enclosure or threaded fitting with tight seals

Your chosen concept is:


Ex e Increased Safety – Category 2, Zones 1,2 (Gas)
• Ex e IIC T6...T1 Gb Ta = –40°C to 60°C
• Standard EN IEC 60079-7 refers
• Design ensures no arcs, sparks or hot surfaces that could ignite an explosive mixture with a minimum IP54 enclosure rating
• Sensors incorporate a suitable heavy duty enclosure or threaded fitting with tight seals

Your chosen concept is:


Ex ia Intrinsically Safe – Category 1, Zones 0,1,2 (Gas) & 20,21,22 (Dust)
• Ex ia IIC T6...T1 Ga Ta = –40°C to 60°C
• Ex ia IIIC T80°C...T440°C Da
• Standard EN IEC 60079-11 refers
• Designed to limit the energy of arcs or sparks that could potentially ignite an explosive mixture
• Sensors used in this area must be wired through a suitably approved barrier
• Optional approved 4 to 20mA transmitters available

Your chosen concept is:


Ex nA Non-Sparking – Category 3, Zone 2 (Gas)
• Ex nA IIC Gc T6…T2
• Standard EN IEC 60079-15 refers
• No arcs, sparks or hot surfaces

Your chosen concept is:


Ex tb Enclosure – Category 2, Zones 21, 22 (Dust)
• Ex tb IIIC T80°C…T440°C Db
• Standard EN IEC 60079-31 refers
• Protects against combustible and conductive dusts, rugged tight enclosures are used

Your chosen concept is:


Ex tc Non-Sparking – Category 3, Zone 22 (Dust)
• Ex tc IIIC T85°C...T450°C Dc
• Standard EN IEC 61241 refers
• Protects against combustible dusts
• Sensors incorporate a suitable heavy duty enclosure with IP6X seal

3. Sheath Material


4. Sheath Diameter


5. Sheath Length


 mm*

6. Types of Sensing Junction


Illustration Select
INSULATED Junction
Duplex Element Required? (please tick box)
Triplex Element Required? (please tick box)

7. Termination Style


Illustration Select
Brass Entry Gland
Stainless Steel Entry Gland

Thread Size:

End Seal Temperature Rating:

8. Extension Leads


Illustration Select
PVC (rated to 105ºC)
End Seal rated to 120ºC
PFA (rated to 250ºC)
End Seal rated to 230ºC
Fibreglass (rated to 480ºC)
End Seal rated to 285ºC
Colour Codes available to IEC 60751
Please enter Cable length in metres

 mtrs

9. Optional Compression Fitting


10. Quantity Required


Contact Details


Company Name


Your Name


Email


Telephone


Additional Information


If your enquiry is for more than one style of sensor, please email us with your requirements or use the box below



Send Enquiry  
BACK TO TOP
IECEx Thermocouples with Pot Seal

IECEx Thermocouples with Die Cast Alloy Head and Process Connection

IECEx Thermocouples with Die Cast Alloy Head

IECEx Thermocouples with St. / Steel Head

IECEx Thermocouples with St. / Steel Head and Process Connection

IECEx Thermocouples with Dual Entry Head

IECEx Thermocouples with Dual Entry Head and Process Connection

IECEx Thermocouples with Spring Loaded Terminal Block

IECEx Thermocouples with Terminal Entry Gland

IECEx Thermocouples with Terminal Entry Gland and Process Connection

IECEx Spring Loaded Thermocouples

IECEx Thermocouple Feedthroughs
IECEx RTD Pt100 Sensors with Pot Seal

IECEx RTD Pt100 Sensors with Die Cast Alloy Head and Process Connection

IECEx RTD Pt100 Sensors with Die Cast Alloy Head

IECEx RTD Pt100 Sensors with St. / Steel Head

IECEx RTD Pt100 Sensors with St. / Steel Head and Process Connection

IECEx RTD Pt100 Sensors with Dual Entry Head

IECEx RTD Pt100 Sensors with Dual Entry Head and Process Connection

IECEx RTD Pt100 Sensors with Spring Loaded Terminal Block

IECEx RTD Pt100 Sensors with Terminal Entry Gland and Process Connection

IECEx RTD Pt100 Sensors with Terminal Entry Gland

IECEx Spring Loaded RTD Pt100 Sensors
IECEx 4 to 20mA Indicators

IECEx Temperature Transmitters

IECEx Compression Fittings

IECEx Terminal Heads

IECEx Pressure and Vacuum Feedthroughs



© 2014- TC Measurement & Control Pty Ltd, PO Box 7777, Oakleigh, VIC 3166
Tel.: 03 9543 8433, Fax: 03 9543 8466, Email: info@tcaus.com.au







1 Thermocouple Type Temperature Range (continuous) Temperature Range
(short term)
K Nickel Chromium vs
Nickel Aluminium
0°C to +1100°C -180°C to +1350°C
T Copper vs Constantan -185°C to +300°C -250°C to +400°C
J Iron vs Constantan +20°C to +700°C -180°C to +750°C
N Nicrosil vs Nisil 0°C to +1100°C -270°C to +1300°C
E Nickel Chromium vs Constantan 0°C to +800°C -40°C to +900°C
R Platinum - 13% Rhodium vs
Platinum
0°C to +1600°C -50°C to +1700°C
S Platinum - 10% Rhodium vs
Platinum
0°C to +1550°C -50°C to +1750°C
B Platinum - 30% Rhodium vs
Platinum 6% Rhodium
+100°C to +1600°C +100°C to +1820°C
Temperature ranges refer to the thermocouple type.
The temperature range of the sensor may deviate from the above,
please refer to the product description for more details
2 Sheath Material Max.
Temperature
Standard Sheath Materials
321

321 Stainless Steel

800°C
310 310 Stainless Steel 1100°C
600 Inconel 600 1100°C
Specialized Sheath Materials
114 Nicrotherm DTM 1250°C
156 Hastelloy X 1220°C
446 AISI 446 1150°C
800 Incoloy 800 1100°C

INSULATED
Hot junction insulated from sheath. Gives floating output with typical insulation resistance in excess of 100 megohms


Assemblies with pot seals are supplied with short tails as shown. However, where leads are several metres or more long, it is more suitable to have an overall sheathed cable. We recommend the following cables.