Products

Notes for Intrinsically Safe Applications

Specifying Sensors for Ex ia Circuits
All thermocouple and RTD sensors shown in this catalogue are suitable for use in intrinsically safe (IS) applications to Zone 0 when used with an appropriate barrier. The full classification is Ex II 1 G Ex ia IIC Ga. The mineral insulated construction gives suitable insulation resistance between conductors (minimum 1000 M Ω) to guarantee conformance.

The barrier isolates the signal from the hazardous area and no further certification of the sensor is necessary.

When a 4~20mA transmitter is selected this is also Ex ia approved. When specifying sensors for IS areas please add IS after the type reference i.e. 52-IS and we will provide the following documentation with the order:
  • TC Ltd Ex ia certificate of conformity & letter of conformity from TrAC Global Ltd (our notified body)
  • Ex ia tags
  • IECEx certificate for transmitter (if required)
  • All cables are supplied with blue outer sheath
  • All terminal heads are supplied in stainless steel (die cast alloy is not permitted in IS areas)
BACK TO TOP
IECEx Thermocouples with Pot Seal

IECEx Thermocouples with Die Cast Alloy Head

IECEx Thermocouples with Die Cast Alloy Head and Process Connection

IECEx Thermocouples with St. / Steel Head

IECEx Thermocouples with St. / Steel Head and Process Connection

IECEx Thermocouples with Dual Entry Head

IECEx Thermocouples with Dual Entry Head and Process Connection

IECEx Thermocouples with Spring loaded terminal block

IECEx Thermocouples with Terminal Entry Gland

IECEx Thermocouples with Terminal Entry Gland and Process Connection

IECEx Spring Loaded Thermocouples

IECEx Thermocouple Feedthroughs
IECEx RTD Pt100 Sensors with Pot Seal

IECEx RTD Pt100 Sensors with Die Cast Alloy Head

IECEx RTD Pt100 Sensors with Die Cast Alloy Head and Process Connection

IECEx RTD Pt100 Sensors with St. / Steel Head

IECEx RTD Pt100 Sensors with St. / Steel Head and Process Connection

IECEx RTD Pt100 Sensors with Dual Entry Head

IECEx RTD Pt100 Sensors with Dual Entry Head and Process Connection

IECEx RTD Pt100 Sensors with Spring loaded terminal block

IECEx RTD Pt100 Sensors with Terminal Entry Gland

IECEx RTD Pt100 Sensors with Terminal Entry Gland and Process Connection

IECEx Spring Loaded RTD Pt100 Sensors
IECEx 4 to 20mA Indicators

IECEx Temperature Transmitters

IECEx Compression Fittings

IECEx Terminal Heads

IECEx Pressure and Vacuum Feedthroughs



© 2006- TC Measurement and Control, Inc, PO Box 65, Hillside, IL 60162
Tel.: 877 249 1777, Fax: 708 449 0777, Email: info@tc-inc.com